In today's high-definition surveillance camera system applications, optical fiber is a way to provide the best bandwidth performance in all connection modes. When using optical fiber transmission systems, the image quality of the system is only limited by the three factors of the camera, the environment and the monitor, and the optical fiber transmission system can transmit the image picture to a very distant place without any distortion of the signal. It will not detract from the sharpness or detail of the picture. It can be said that the optical fiber transmission system is the lifeline of the entire monitoring system.

First, the type of fiber

The optical fibers are classified into indoor optical fibers, outdoor optical fibers, branch optical fibers, and distribution optical fibers according to different occasions.

According to laying methods: Self-supporting overhead optical fiber, pipeline optical fiber, armored buried optical fiber and submarine optical fiber.

Divided by optical fiber structure: beam tube type fiber, layered stranded optical fiber, skeleton type optical fiber, clasp type optical fiber, ribbon type optical fiber, non-metal optical fiber and branchable optical fiber.

Divided by purpose: optical fiber for long-distance communication, short-distance outdoor optical fiber, mixed optical fiber and in-building optical fiber;

Fibers can be classified into single-mode and multi-mode according to the transmission mode, and monitoring generally uses single-mode fiber.

Single-mode fiber: Optical fiber that transmits only one mode of optical signal. Conventionally, there are G.652, G.653, G.654, G.655, and other transmission class classifications. The transmission distance of single-mode fiber can reach several tens of kilometers. The single-mode fiber transmits only the main mode, which means that light is transmitted only along the inner core of the fiber. This completely avoids the mode dispersion and makes the transmission bandwidth of the single-mode fiber very wide. Therefore, it is suitable for large-capacity, long-distance optical fiber communication. The wavelength of light used by a single-mode fiber is 1310 nm or 1550 nm.

Multi-mode optical fiber: Optical fiber that can transmit multiple modes of optical signals, which is G.651 grade. It is divided into OM1, OM2, OM3 according to the optical mode, and the farthest transmission distance of multi-mode optical fiber transmits the 2 megahertz signal. In a multi-mode optical fiber, multiple modes are transmitted in an optical fiber at a certain operating wavelength. This kind of optical fiber is called a multi-mode optical fiber. Due to dispersion or aberration, the optical fiber has a relatively narrow transmission band and transmission capacity. Smaller, shorter distances.

Second, fiber laying methods and requirements

The conventional outdoor optical fiber is a container with a loose tube as the core, which is the most common fiber core laying method. The indoor optical fiber is usually tightly laid. The core of the large number of optical fibers is also combined in the form of a ribbon to lay the fiber. core.

Fiber laying requirements: The bending radius of the fiber should be at least 15 times the outer diameter of the fiber, and should be at least 20 times during the construction process. When laying the fiber, the rotation of the fiber plate should be synchronized with the deployment speed, and the fiber indexing speed is general. 15 meters per minute; when laying out the optical fiber, the optical fiber should be kept at a loose arc at the outlet, and the buffering margin should be kept. It should not be too much to avoid the back buckle of the optical fiber; the length of the optical fiber reserved at both ends is 5-10 meters. When laying optical fiber, labels should be made and the line should be filled; all optical fibers should not be exposed.

Third, the choice of optical core

The number of fiber cores is the number of glass fibers contained in each fiber. The following small series gives you some methods to determine the number of fiber cores.

First, the number of routing points in the layer is clearly known, the number of switches is calculated, and whether the connections between the switches are stacked or unstacked. If it is stacked and the core switch is dual-system hot standby redundancy, 6 cores are sufficient (2 cores each with 2 cores and 2 cores redundant). If you do not stack a switch to 4 cores, the number of switches is multiplied by 4 plus 4 cores of redundancy. (Note: Redundancy: as long as it is more than the use of, redundant is called redundant master and standby: one used, the other is exactly the same as the backup; hot backup: both at work; cold backup: the backup device is in standby mode.)

Experiences and practices: Each floor wiring closet (horizontal wiring cabinet), set up an optical fiber, generally six-core: two-core use, two-core spare, two-core redundancy; also use eight-core optical fiber. The standard minimum configuration is 2 cores per 48 points. Of course, 48 points can be selected for 4 cores, because 2 cores are the smallest units of fiber, and it is more appropriate to keep 2 cores as a backup.

The above is a description of how to determine the number of fiber cores. Everyone can find out. Backup can be chosen because of people, so the fiber out of the number of differences in the number of more, according to the selection of the election is only to ensure a minimum selection plus a backup core number on it.

Fourth, pay attention to

The selection of optical fiber is based on the number of optical fibers and the type of optical fiber, and the outer sheath of the optical fiber is also selected according to the use of the optical fiber. Attention should be paid to the following points when selecting the optical fiber:

1. When the optical fiber is directly buried outdoors, the armored optical fiber should be selected. When it is overhead, two or more black plastic outer sheathed optical fibers of the reinforcing ribs may be used.

2. The optical fiber used in a building should pay attention to the characteristics of its flame retardant, poison and smoke. Generally, in the pipeline and in the forced ventilation, the type of flame retardant and smoke can be used. In the exposed environment, flame retardant should be used. , smokeless and non-toxic types.

3. In the vertical wiring in the building, the layered stranded optical fiber can be used; in the horizontal cabling type, the branching optical fiber can be selected.

4. Optional multi-mode optical fiber with a transmission distance of less than 2km; optional relay or single-mode optical fiber over 2km.

The above are just a few of the issues considered from the application side, and they need to be flexibly implemented. In fact, the wiring environment is complex and diverse, and various problems may arise at any time. This requires us to strictly implement the wiring standards in planning and construction. When problems are encountered and the analysis is flexible, it will be resolved satisfactorily.

As the name suggests, Diaphragm Metering Pump using a special design and processing of flexible diaphragm instead of the piston, under the action of the drive mechanism to achieve reciprocating motion, complete the suction - discharge process. Due to the segregation of the diaphragm, the isolation between the metering fluid and the driving lubrication mechanism is realized in the structure. High-tech structural design and the selection of new materials has greatly improved the service life of the diaphragm, coupled with excellent corrosion resistance of composite materials, diaphragm metering pumps become the main application of fluid measurement pump type.

In the diaphragm-type Metering Pump family members, the hydraulic diaphragm metering pump as a result of the use of hydraulic oil evenly drive the diaphragm, to overcome the mechanical direct drive mode under the pump diaphragm too concentrated shortcomings, to enhance the diaphragm life and working pressure ceiling. In order to overcome the single diaphragm metering pump may occur due to damage caused by the diaphragm damage, and some metering pumps equipped with a diaphragm breakage sensor to achieve the diaphragm when the automatic chain protection; with double diaphragm structure of the pump head to further improve its safety Sex, suitable for security protection is particularly sensitive to the application.

As a kind of diaphragm type metering pump, the electromagnetic driven metering pump generates the pulsating driving force with the electromagnet, which saves the motor and the speed change mechanism, makes the system compact and compact, it is an important branch of the small range low pressure metering pump.

Precision metering pump technology has been very mature, the fluid metering capacity of up to 0-100,000l / h, working pressure up to 4000bar, the scope of work covers all areas of industrial production requirements.


If you want to buy Mechanical Diaphragm Metering Pump, Solenoid Diaphragm Metering Pump(Electromagnetic Metering Pump), Water Treatment Dosing Pump , Plastic Chemical Diaphragm Metering Pump, please contact us.


Diaphragm Metering Pump

Diaphragm Metering Pump,Mechanical Diaphragm Metering Pump,Solenoid Diaphragm Metering Pump,Plastic Chemical Diaphragm Metering Pump,Water Treatment Dosing Pump,Electromagnetic Metering Pump

Zhejiang Ailipu Technology Co., LTD. , http://www.alipu.com